|
» »
| Retail: | $3,998.00 | Minimum Advertised Price: The lowest price we can show | $1,999.00 |
Free "Ground" Shipping! (US only) or For Our Best Price Call 877-746-4873
or
|
Crown XTi 6002 | Power AmplifierSKU: XTi 6002
With the Brand New Crown XTi 2 Series, you'll be getting one of the most innovative and powerful amplifiers on the market today. The Crown XTi 6002 delivers at an exceptional performance and value while eliminating the need for external EQs, crossovers, and limiters, immediately saving you money and rack space. Using the same framework technology as Crown's I-Tech HD Series amplifiers, the Crown XTi 6002 provides revolutionary control with its PeakX Plus limiters allowing for control over threshold, attack, and release times. The XTi6002 also has enhanced the Subharmonic Synth so you can easily manage frequency, gain and filter type, allowing for application-specific tuning. Crown has pushed the boundary for performance, features, and value with the new XTi 6002.
Read the PRESS RELEASE
Description:
There's no debate – when you choose Crown's XTi 2 Series, you're choosing one of the most powerful and innovative amplifiers on the market today. That's because the all-new XTi 2 Series amps continue to set the standard for unmatched performance and value, delivering the goods night after night without breaking a sweat.
Features:
-
Peakx Plus™ Limiters provide the ultimate in system performance and protection by allowing full control over threshold, attack, and release
-
Enhanced Subharmonic Synth section provides user control over frequency, gain and filter type for system-specific tuning
-
3 User-defined fan mode controls – normal, early and fullspeed – for matching fan performance to a specific application
-
New system monitoring provides software visibility of AC line voltage and power supply temperature
-
Integrated cast-aluminum handles for easy handling and enhanced durability
-
Locking power cord clip provides a secure connection between the amplifier and power cord
-
Updated HiQnet Band Manager™ and System Architect™ control software
-
Increased number of presets to a total of 30; 29 of which are user definable
|
|
XTi 1002 |
XTi 2002 |
XTi 4002 |
XTi 6002 |
|
2 Ohm Stereo (per ch.) |
700W |
1000W |
1600W |
3000W |
|
4 Ohm Stereo (per ch.) |
500W |
800W |
1200W |
2100W |
|
8 Ohm Stereo (per ch.) |
275W |
475W |
650W |
1200W |
|
8 Ohm Bridge-Mono |
1000W |
1600W |
2400W |
4200W |
|
4 Ohm Bridge-Mono |
1400W |
2000W |
3200W |
6000W |
Integrated Processing:
|
Input EQ
|
6 parametric filters per channel with adjustable Q, ±15 dB boost/cut. Also adjustable high and low shelving filters. This 8-filter EQ section can be bypassed.
|
|
Crossover Filters
|
Highpass and Lowpass per channel. Butterworth 6/12/18/24 dB per octave. Linkwitz-Riley 24/48 dB per Octave. Also includes ± 15 dB bandpass gain and polarity control.
|
|
Output EQ
|
8 parametric filters per channel with adjustable Q, ±15 dB boost/cut. This 8-filter EQ section can be bypassed.
|
|
Delay
|
For signal alignment of driver; 50 mS of total delay.
|
|
SubHarmonic Synth
|
Takes the low-frequency content of the input signal and "synthesizes" a new signal that is the same as the input signal but one octave lower. The new synthesized signal is then mixed with the original signal to create the effect. New: Users now have control over frequency, gain, and filter type.
|
|
Peakx™ Plus Limiter
|
User defeatable limiter that allows users to control Threshold, Attack, and Release times.
|
|
Presets
|
30 total presets, 29 of which are user-definable.
|
Performance:
|
Sensitivity (for full rated power at 4 ohms)
|
1.4 Vrms
|
|
Frequency Response (at 1 watt, 20 Hz - 20 kHz)
|
+0 dB, –1 dB
|
|
Signal-to-Noise Ratio (below rated 1kHz power at 8 ohms)
|
XTi1002/2002/4002: 100 dB (A weighted)
XTi6002: 103 dB (A weighted)
|
|
Total Harmonic Distortion (THD)
|
< 0.5%
|
|
Damping Factor 20 Hz to 1 kHz
|
> 500
|
|
Crosstalk (below rated power)
|
20 kHz - 1 kHz: > 70 db
|
|
Input Impedance (nominal)
|
20k ohms balanced, 10k ohms unbalanced
|
|
Maximum Input Signal
|
+22 dBu typical
|
|
AC Line Voltage and Frequency Configurations
|
100 VAC, 120 VAC, 220-240 VAC 50/60 Hz
|
|
AC Line Current
(120 VAC amplifier playing 1/8 power pink noise into 4 ohms per ch)
|
XTi1002: 6.8A; no more than 38W at idle
XTi2002: 8.3A; no more than 38W at idle
XTi4002: 10.5A; no more than 38W at idle
XTi6002: 15.3A; no more than 180W at idle
|
|
Operating Temperature
|
0°C to 40°C at 95% relative humidity (non-condensing)
|
|
Signal Indicator
|
Green LED, one per channel, illuminates when a very low-level signal is present at input (may be used for troubleshooting cable runs).
|
|
–10 Indicator
|
Green LED flashes when output signal exceeds -10 dB below clip.
|
|
–20 Indicator
|
Green LED flashes when output signal level exceeds -20 dB below clip.
|
|
Ready Indicator
|
Green LED, one per channel, illuminates when the amplifier is ready to produce audio.
|
|
Clip Indicator
|
Red LED, one per channel, turns on at the threshold of audible distortion
|
|
Temp Indicator
|
Red LED, one per channel, illuminates under excessive temperature conditions
|
|
Power Indicator
|
Blue LED illuminates when the amplifier has been turned on and has power
|
MORE...
|